Roof Flashings: Why Leaks Appear at the Edges of Your Building

If the water in your building appears along the walls rather than in the middle of the floor, your roof flashings are the first thing worth looking at.

Flashings close the gap wherever the roof meets something that is not roof. A parapet. A wall. A plant platform. A change in roof level. Nobody specifies a building because of its flashings, and on most roofs they occupy a tiny fraction of the total area.

They also account for a disproportionate share of the leaks we get called to.

What a flashing has to do

Every other part of a roof has one job, which is to shed water downhill. A flashing has a harder one.

It has to bridge two separate elements that are built differently, move differently and were often installed by different contractors at different times. On one side is a profiled metal roof sheet that expands and contracts across its length. On the other is a block wall, a concrete parapet or a steel frame that barely moves at all.

The flashing sits across that difference and has to stay watertight while one side moves and the other does not. That is the whole problem in one sentence, and it explains why flashings tend to fail before the sheets around them.

The types you will have on an industrial roof

Parapet and side (wall) flashings. Where the roof runs into a vertical face. Usually the most heavily worked junction on the building, because it absorbs the most differential movement.

Counter-flashings. The upper piece that laps over the base flashing and keeps water from getting behind it. Often chased into the wall or fixed to it. When a counter-flashing lifts or its sealant fails, water runs behind the base flashing and the leak appears some distance away.

Ridge and peak flashings. Closing the top of the roof where two slopes meet.

Valley flashings. Where two slopes run into each other, carrying a concentrated volume of water. Any failure here is a large one.

Penetration flashings. Around AC units, extract fans, pipe stacks and cable entries. Retrofit penetrations tend to be the least carefully detailed parts of the structure, since they are usually cut in after the building was finished by an equipment installation contractor.

Expansion joint covers. Where the building is designed to move. These are supposed to move, which is precisely why specialised waterproofing treatment is required to keep these areas watertight.

How they fail in UAE conditions

Sealant ageing. Sealants at junctions between two dissimilar materials are worked harder than sealants between two steel sheets, because the differential movement is greater, so they reach the end of their service life earlier.

Fixation failure. Once a flashing is no longer held tight against the substrate, wind lifts it, and water gets underneath.

Wind damage. Flashings sit at the edges and the high points of a roof, where wind uplift is strongest.

Trapped water and corrosion. Where a flashing meets a parapet, dust and sand collect in the angle and hold moisture against the metal long after the rain has gone. Corrosion often starts in that line before it starts anywhere else on the roof.

Retrofit work. Anything installed on the roof after handover involved cutting or lifting a flashing.

Why leaks show up away from the flashing

This is the part that misleads people, and it is why flashing leaks get mistaken for sheet leaks.

Water that gets behind a counter-flashing does not drop straight down. It runs along the inside face of the parapet, then along a purlin, then falls wherever the structure gives it a reason to. The wet patch on your floor can be several metres from the point where water actually entered.

So a repair aimed at the ceiling stain seals a sound section of roof and leaves the flashing open. The next rain produces the same leak, and the roof gets a reputation for being unfixable when the real problem is that nobody traced it.

Our post on finding a leak in an industrial metal roof covers how the entry point is traced properly.

What is involved in making them watertight

Flashings are a detail job rather than an area job, and they are treated as such.

Within a waterproofing system, flashings and counter-flashings are one of the named critical areas, alongside seams, sidelaps, fastenings, skylights, penetrations and gutters. Each one is addressed individually: old sealant is removed in full rather than in the loose sections, the substrate is cleaned, corrosion is neutralised, fixations are made good, and the junction is sealed with an elastomeric sealant that can stretch and recover with the movement rather than cracking against it.

Where a flashing has been damaged, badly cut during a retrofit, or corroded through, the flashing itself is replaced.

The reason this matters: a coating applied over a flashing whose sealant has already failed bonds to that failed sealant. Preparation is what the warranty rests on, which is covered in more detail in our post on TOPPS® waterproofing systems.

When flashings are telling you something bigger

A single failed flashing is a repair. Flashings failing across the roof usually means the sealant everywhere is the same age and has reached the same point in its life, in which case treating one junction only moves the problem along.

That is the point at which a full restoration becomes the economical route rather than a sequence of separate visits. Our post on restoration or replacement sets out how that decision is made.

Getting them checked

Flashings are inspected as part of every roof condition survey we carry out, alongside the condition of the seams, fastenings, skylights, penetrations and drainage.

Solaroofing has been waterproofing metal roofs in the UAE for over 30 years, for clients including the UAE Ministry of Defence, Dubai Police, Dubai Civil Aviation Authority and Drydocks World, alongside factories and warehouses across Jebel Ali, Dubai Investments Park, National Industries Park, Dubai Industrial City, Al Quoz Industrial Area, Musaffah, ICAD and numerous other industrial areas within the UAE.

If water is appearing along the edges of your building, a survey will tell you where it is getting in. It is free and the report is yours to keep.

Frequently Asked Questions

What are roof flashings? Flashings are materials that seal junctions wherever a roof meets something that is not roof: a parapet, a wall, a change in roof level, or a penetration such as an AC unit or pipe stack. Their job is to keep water out of a joint between two elements that are built differently and move by different amounts.

Why do roof flashings fail? Because they sit across a junction between dissimilar materials. A metal roof sheet expands and contracts considerably through the daily temperature cycle while a block wall or concrete parapet barely moves.

Why does the leak appear away from the flashing? Water that gets behind a flashing runs along the inside face of the parapet and then along a purlin before it drops, so the wet patch indoors can be several metres from where the water entered. This is why repairs aimed at the ceiling stain often fail: they seal a sound part of the roof and leave the actual entry point open.

Can a flashing be resealed, or does it need replacing? Resealing is appropriate where the flashing itself is sound and the sealant or fixations have failed, which covers the majority of cases. Replacement is needed where the flashing has corroded through, been damaged, or was cut during a retrofit and not reinstated properly. A survey establishes which applies in each case.

How often should roof flashings be inspected? Twice a year suits most facilities, once before the rain season and once after. Add a specific check after any rooftop work by other contractors, since flashings are routinely cut or lifted to install equipment and are not always reinstated properly afterwards.

Water is appearing along our walls after rain. Is that a flashing problem? It frequently is, since water entering at a parapet or wall abutment typically shows along the building's edges. It can also indicate a drainage problem, where a gutter over capacity sends water backwards beneath the sheet ends. The two need different work, so establishing which one you have comes before any quotation.